KeyValueDescription
buf72 02 04 11 00 00 00 34 00 0A 00 00 00 00 00 00 00 00 00 00 01 0A 00 00 00 00 00 00 00 00 00 00 02 06 00 00 00 00 00 00 03 02 00 53 05 02 00 00 80 02 F5 53 81 06 00 00 00 00 00 00
buf_len60
parsed1
sense_typedescriptor
responsecurrentError was about the IO that failed
sense_key0x2
sense_key_nameNOT_READYDisk is not ready for commands, if this persists for long it is likely the disk is bad but normally this error can be seen when the disk starts up. More
asc0x04
ascq0x11
asc_nameLOGICAL UNIT NOT READY, NOTIFY (ENABLE SPINUP) REQUIRED
information_valid0
information0
cmd_specific_valid1
cmd_specific0
fru_code_valid1
fru_code0x53
vendor_unique0xf553