KeyValueDescription
buf70 00 06 00 4E 63 62 18 00 00 00 00 29 07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
buf_len32
parsed1
sense_typefixed
responsecurrentError was about the IO that failed
sense_key0x6
sense_key_nameUNIT_ATTENTIONDevice sent a notice that something material has changed in it, this normally happens when a mode parameter changed or the device was restarted or the storage fabric had a reset. The command needs to be retried as there was no fault with the command itself. More
asc0x29
ascq0x07
asc_nameI_T NEXUS LOSS OCCURRED
information_valid0
information0
cmd_specific_valid1
cmd_specific0
fru_code_valid1
fru_code0x0
vendor_unique0x0
Attempt additional SCSI sense buffer decoding. To learn more about SCSI Sense visit the page about making sense of SCSI Sense