KeyValueDescription
buf70 00 06 00 00 00 00 18 00 00 00 00 29 07 54 00 00 00 00 00 F5 54 00 00 00 00 00 00
buf_len28
parsed1
sense_typefixed
responsecurrentError was about the IO that failed
sense_key0x6
sense_key_nameUNIT_ATTENTIONDevice sent a notice that something material has changed in it, this normally happens when a mode parameter changed or the device was restarted or the storage fabric had a reset. The command needs to be retried as there was no fault with the command itself. More
asc0x29
ascq0x07
asc_nameI_T NEXUS LOSS OCCURRED
information_valid0
information0
cmd_specific_valid1
cmd_specific0
fru_code_valid1
fru_code0x54
vendor_unique0xf554
Attempt additional SCSI sense buffer decoding. To learn more about SCSI Sense visit the page about making sense of SCSI Sense

Contact Baruch Even for inquiries and suggestions.